LynkNano LN-T1000 — User Manual
Hydrogen Water Tumbler · 1 L · User Manual
Bookmark this page — it is kept up to date.
1. Parts
The parts of your tumbler
2. In the box
- Tumbler body and base
- Lid with straw
- Clip-on carry strap
- USB-C charging cable
- Printed manual
3. Specification
| Model | LN-T1000 |
| Capacity | 1 L (33.8 fl oz) |
| Body | 316 stainless steel, double-wall vacuum insulated |
| Cell | SPE / PEM |
| Electrode | platinum-coated titanium |
| Lid | flip-and-rotate straw lid |
| Battery | 4000 mAh lithium-ion, 3.7 V, 14.8 Wh |
| Charging | USB-C, 5 V 2 A |
| Cycles | 10 min / 20 min |
| Self-clean | 3 min cycle |
| Net weight | 680 g |
| Water temperature | 0–60 °C (32–140 °F) |
| Colours | black, blue, green, pink |
| Origin | Made in China |
Hydrogen concentration
| 10 min | 1,500–2,000 ppb |
| 20 min | 3,000+ ppb |
Measured in the sealed chamber as the cycle ends. Hydrogen leaves water quickly once the tumbler is opened, so concentration falls from the moment you pour.
4. First use
- Separate the body from the base. Hold the base steady and twist the body counter-clockwise.
- Remove the protective cap inside the base by twisting it counter-clockwise. Discard it. This is fitted for transport only.
- Refit the body to the base and twist clockwise until secure.
- Rinse two or three times with clean drinking water.
- Charge it fully before the first cycle.
Weak output on the first run? Fill with clean water and leave it to stand for an hour or two before pressing start. The membrane needs to be wet to work, and it comes up to full output after a few cycles.
5. How it works
An SPE/PEM cell sits in the base. A proton exchange membrane splits a small amount of water at platinum-coated titanium electrodes, so hydrogen forms on one side and the by-products on the other. Oxygen, ozone and residual chlorine vent out through the base instead of staying in the water. Nothing is added to the water and nothing is taken out of it.
This tumbler has no filter. It does not purify water and it will not make unsafe water safe.
6. The button
Everything is controlled from the single button on the base. There is no app and no phone pairing.
| Press once | Turns the tumbler on. Press again to turn it off. |
| Press once more | Starts a 10-minute cycle, 1,500–2,000 ppb. |
| Press twice quickly | Starts a 20-minute cycle, 3,000+ ppb. |
| Press and hold 3 s | Starts the 3-minute self-clean. |
Light colours
The light goes out when the cycle finishes.
7. How to use
- Fill with drinking water. Do not fill past the maximum line.
- Close the lid and stand the tumbler upright.
- Press the button once to turn it on, then once more for a 10-minute cycle, or twice quickly for 20 minutes.
- The blue light goes out when the cycle finishes.
- Drink it straight away.
Hydrogen leaves the water over time whether the lid is on or off. The first few minutes hold most of what the cycle produced.
Which water to use
Use bottled, filtered or other drinking water, at room temperature. Do not use boiling water — it will damage the product.
Do not put any other liquid in the tumbler. No salt water, fruit juice, tea, coffee, soy milk, beer, fizzy drinks, alcohol or milk. They will damage the cell, and damage caused this way is not covered by the warranty.
8. Self-clean
Hard water leaves mineral scale on the electrode plate, and scale reduces hydrogen output.
- Fill with clean water.
- Press and hold the button for 3 seconds. The green light comes on and a 3-minute cycle runs.
- Pour the water away when it finishes. The water produced during the self-clean is not for drinking.
- Rinse once with fresh water.
Once every 5–7 days is enough. In hard-water areas you can run it more often — it does not shorten the product's life.
Monthly deep clean
Fill with a 1 : 3 mix of white vinegar and water, run one 10-minute cycle, pour it out, then rinse two or three times with fresh water. This removes mineral buildup the normal cycle leaves behind and restores output.
9. Charging
Connect the supplied USB-C cable to the port on the base and plug it into a standard 5 V USB power source. The light shows red while charging and green when the charge is complete. Charge at room temperature, and never while the tumbler is wet.
10. Care and storage
- Hand wash the lid and straw. Wipe the body with a damp cloth.
- Do not put any part in a dishwasher.
- Do not immerse the base in water.
- If you will not use the tumbler for a long time, leave a little water inside. The membrane must stay damp. Storing it bone dry will damage the cell.
- Charge the battery every few months during long storage.
- Coming back after a long break: fill with clean water, let it stand a couple of hours, then run the self-clean and one normal cycle before you drink.
- Keep it out of direct sunlight and away from heat.
11. Warnings
- Contains a lithium-ion battery. The battery is built in and is not user-replaceable. Do not crush, puncture, incinerate or expose to heat.
- If the tumbler swells, overheats or leaks, stop using it.
- At end of life, dispose of it through a battery recycling point — not with household waste.
- Do not use boiling water. Keep water at or below 60 °C (140 °F).
- Avoid strong impact and do not drop the product.
- Keep away from children and from open flame.
- Do not immerse the base or charge it while wet.
- Do not disassemble, modify or attempt to repair the tumbler. There are no user-serviceable parts inside.
- Stop using the tumbler if it or the cable is damaged.
- Do not drink the water if it looks, smells or tastes wrong.
- This product is not a medical device and is not a substitute for medication.
California Proposition 65
WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
12. Troubleshooting
| Will not start | Battery flat | Charge it fully and try again. |
| Fewer bubbles than usual | Mineral scale on the electrode plate | Run the self-clean, then the monthly vinegar clean. |
| Weak output after storage | The membrane dried out | Fill with clean water, leave it two hours, then run two or three cycles. |
| Unusual taste or smell | Poor quality water, or cleaning residue | Rinse thoroughly and switch to a better quality drinking water. |
| Short run time | Battery capacity reduces with age | Charge fully. If it is still short inside the warranty period, contact us. |
| Metallic taste | Possible fault | Stop using it and contact us. |
13. Common questions
How soon should I drink it?
Straight after the cycle. Hydrogen is the smallest molecule there is and it escapes steadily, whether the lid is on or off.
Does it filter or purify the water?
No. There is no filter. Put drinking water in — the tumbler adds dissolved hydrogen gas and nothing else.
Do I need filters or cartridges?
No. There is nothing to replace and nothing to reorder. The electrode plate is cleaned by the self-clean cycle rather than swapped out.
Can I put hot coffee or tea in it?
No. Drinking water only. Other liquids damage the cell and void the warranty.
Is there an app?
No. Everything runs from the button on the base.
Why 316 stainless and not 304?
316 resists corrosion from citrus and salt better than 304, so it does not stain or leave a metallic edge on the water.
14. Warranty and contact
1-year limited warranty from the date of delivery. Full terms: lynknano.com/warranty
Support: lynknanos@gmail.com
LynkNano™ · Model LN-T1000 · Made in China
Distributed by Framoon LLC

